Jaincolab Manufacturers is a leading Lighting and Building Control Systems Manufacturer, Supplier, and Exporter in India, United States, Indonesia, Brazil, Bangladesh, Mexico, Japan, Egypt, Philippines, Democratic Republic of the Congo, Vietnam, Iran, Turkey, Tanzania, United Kingdom, France, South Africa, Italy, Kenya, Colombia, Sudan, Uganda, South Korea, Argentina, Afghanistan, Yemen, Angola, Morocco, Poland, Uzbekistan, Mozambique, Malaysia, Ghana, Saudi Arabia, Peru, Madagascar, Côte d’Ivoire, Cameroon, Niger, Venezuela, Australia, Syria, Mali, Burkina Faso, Sri Lanka, Malawi, Zambia, Chad, Kazakhstan, Somalia, Chile, Senegal, Ecuador, Cambodia, Zimbabwe, Guinea, Benin, Rwanda, Burundi, Bolivia, South Sudan, Tunisia, Haiti, Belgium, Dominican Republic, Jordan, United Arab Emirates, Honduras, Tajikistan, Papua New Guinea, Portugal, Togo, Sierra Leone, Belarus, Laos, Turkmenistan, Libya, Kyrgyzstan, Nicaragua, Paraguay, Bulgaria, Serbia, Republic of the Congo, Lebanon, Liberia, Central African Republic, Palestine, Oman, Mauritania, New Zealand, Costa Rica, Kuwait, Panama, Croatia, Georgia, Eritrea, Mongolia, Uruguay, Qatar, Namibia, Bosnia and Herzegovina, Moldova, Armenia, Gambia, Jamaica, Lithuania, Albania, Gabon, Botswana, Lesotho, Guinea-Bissau, Slovenia, Equatorial Guinea, Latvia, North Macedonia, Bahrain, Trinidad and Tobago, Timor-Leste, Cyprus, Estonia, Eswatini, Mauritius, Djibouti, Fiji, Comoros, Solomon Islands, Guyana, Bhutan, Luxembourg, Suriname, Montenegro, Malta, Maldives, Cabo Verde, Brunei, Belize, Bahamas, Iceland, Vanuatu, Barbados, São Tomé and Príncipe, Samoa, Saint Lucia, Kiribati, Seychelles, Grenada, Saint Vincent and the Grenadines, Antigua and Barbuda.

Last updated: 16 November 2026

What is in the lighting and building control systems range?

This range has eight trainers for building services and renewable energy courses. Two cover security and fire alarm systems, one covers solid state relays and electronic control, and one covers direct digital control of building services. Four are solar trainers: three on solar water heating and heat absorption, and one demonstrator on solar electric power.

Trainer groups in the building control range

GroupItemsWhat it covers
Alarm systemsSecurity Alarm Trainer (JA-LABCS-9618), Fire Alarm Trainer (JA-LABCS-9625)Basic security and fire alarm systems for students and technicians who will install and maintain them
Control systemsElectronic Control Trainer (JA-LABCS-9619), Training System for DDC Control (JA-LABCS-9624)Solid state relays and semiconductor control; configuration and programming of DDC units for building services
Solar heatingSolar Heat Energy Trainer (JA-LABCS-9620), Solar Energy Trainer, Boiler Type (JA-LABCS-9621), Solar Energy Hot Water System Trainer (JA-LABCS-9622)Solar heat absorption with heat measurement, and solar hot water systems with a separate boiler or an integral tank
Solar electric powerSolar Energy Demonstrator (JA-LABCS-9623)Solar cell operation, battery storage and DC to AC conversion

Alarm and control trainers compared

Each trainer is listed with the details its product page gives.

ProductProduct codeSubjectLearners or skillsMain components
Security Alarm TrainerJA-LABCS-9618Basic security alarm systemsStudents and technicians; installation and maintenanceIntruder alarm control panel with at least two zones, keypad or key switch, PIR detector, magnetic reed contacts, glass-break detector, and siren with strobe or beacon
Fire Alarm TrainerJA-LABCS-9625Basic fire alarm systemsStudents and technicians; installation and maintenanceConventional two-zone fire alarm control panel, optical smoke and heat detectors, break-glass manual call points, and bell or horn sounder with a flashing beacon
Electronic Control TrainerJA-LABCS-9619Solid state relays and their applications; semiconductor theorySwitching loads with SSRs, comparing SSR and electromechanical relay switching, zero-cross switching, and SCR and triac triggeringZero-cross AC solid state relay with a triac or SCR output, optocoupler isolation, about 5 to 30 V DC control input, and lamp and heater loads on 230 V AC
Training System for DDC ControlJA-LABCS-9624Direct digital control of heating, cooling, lighting, electrical and security services, and of industrial processesConfiguration, programming and set-up of DDC unitsProgrammable DDC controllers with universal I/O and BACnet/IP to a supervisory PC; temperature, humidity, carbon dioxide and occupancy sensors; 0 to 10 V damper actuators, fan, heater and lighting loads

Solar trainers compared

ProductProduct codeEnergy typeSystemStorage or outputNotes
Solar Heat Energy TrainerJA-LABCS-9620Solar heatHeat absorption measured in kcal or BTUHeat gained by the water, in kcal or BTU (no storage tank)Small and compact, for classroom and remote-site use
Solar Energy Trainer, Boiler TypeJA-LABCS-9621Solar heatHot water heating, boiler type, with a solar collectorSeparate boiler with a supplementary electric heaterDiagram of the solar collection and control circuit
Solar Energy Hot Water System TrainerJA-LABCS-9622Solar heatHot water heater with an integral tankIntegral storage tank with a supplementary electric heaterThermosiphon circulation with no pump; free-standing frame with adjustable collector tilt
Solar Energy DemonstratorJA-LABCS-9623Solar electricSolar cells with battery storageDC to AC conversionIntroduction to solar electric power generation

How to choose a building control or solar trainer

  • For alarm installation courses, choose the Security Alarm Trainer (JA-LABCS-9618) or the Fire Alarm Trainer (JA-LABCS-9625). Both teach basic systems to students and technicians who will install and maintain them.
  • For building automation, the Training System for DDC Control (JA-LABCS-9624) covers configuration and programming of DDC units for heating, cooling, lighting, electrical and security services.
  • For control electronics, the Electronic Control Trainer (JA-LABCS-9619) covers solid state relays and their applications, with an introduction to semiconductor theory.
  • For solar water heating, compare the two hot water trainers. The boiler type (JA-LABCS-9621) has a separate storage boiler. The hot water system trainer (JA-LABCS-9622) has an integral tank. Both have a supplementary electric heater.
  • For heat measurement on a small set, the Solar Heat Energy Trainer (JA-LABCS-9620) measures solar heat absorption in kcal or BTU. It suits classroom or remote-site use.
  • For solar electricity, choose the Solar Energy Demonstrator (JA-LABCS-9623), which covers solar cells, battery storage and DC to AC conversion. It has a module of about 40 to 90 W, a 12 V battery and an inverter of about 100 to 300 W with a 230 V AC output.

Practicals covered by these trainers

TaskProducts used
Wiring and testing a basic security alarm systemSecurity Alarm Trainer
Wiring detectors and sounders to a fire alarm panel and testing the systemFire Alarm Trainer
Switching loads with solid state relaysElectronic Control Trainer
Configuring and programming a DDC controller for a building serviceTraining System for DDC Control
Measuring the heat absorbed by a solar collectorSolar Heat Energy Trainer
Comparing boiler-type and integral-tank solar hot water systemsSolar Energy Trainer, Boiler Type and Solar Energy Hot Water System Trainer
Charging a battery from solar cells and running an AC load through DC to AC conversionSolar Energy Demonstrator

Who uses these trainers

Polytechnics, ITIs, engineering colleges and vocational centres use these trainers in building services, electrical and renewable energy courses. The alarm trainer pages name students and technicians preparing for installation and maintenance work.

Ordering building control and solar trainers

Quote the product code of each trainer. The product pages list the alarm panels and detectors, the DDC controller and its I/O, the collector size of the solar heat trainer and the module, battery and inverter ratings of the demonstrator. The alarm, boiler-type solar and DDC trainers run on 230 V AC, 50 Hz mains. For the solar trainers, state the collector type you want and whether you need an indoor lamp. Send the list through our contact page.

Electrical ranges related to building control

Building control and solar trainers are part of the Electronics Lab Equipments range from JaincoLab, an electronics lab equipment manufacturer in India.

RangeWhat it covers
Wiring, Distribution and ProtectionElectrical installation, circuit fault and electrical machine trainers
Data Acquisition, Instrumentation and Process ControlPLC trainers, a conveyor system, process panels and temperature and level control trainers
Electrical TechnologyElectrical measurement, transformer and metering, and appliance repair trainers
Electrical Motor ControlA motor control circuit trainer, a motor generator system and sectioned motors
Variac DimmerstatsSingle phase and three phase variacs in panel and portable types
Electronic FundamentalsBasic electricity and electronics trainers, an operational amplifier trainer and automotive electrical trainers
Power Electronics TrainersSCR, triac and UJT trainers, thyristor converters and motor speed control
Breadboard TrainersBreadboard circuit labs, digital and analog labs, and logic trainers
Analog Electronics TrainerTraining boards for diodes, transistors, amplifiers, oscillators, filters and bridges
Digital Electronics TrainerLogic training boards for gates, flip-flops, counters, converters, multiplexers and decoders
OscilloscopesDual trace oscilloscopes, an oscilloscope with digital readout and a frequency counter
Digital Storage OscilloscopesDigital storage oscilloscopes, including dual channel and four channel models
Signal GeneratorsFunction generators, an AM and FM function generator and an RF signal generator
Communication TrainerAmplitude, frequency, pulse and phase modulation trainers, multiplexing and transmission line trainers
Radio and Telephone CommunicationsAM FM radio, CB transceiver, walkie talkie, mobile phone and microwave trainers

Frequently Asked Questions

What is the fill factor of a solar cell and how is it found?
Plot current against voltage while the load changes from a short circuit to an open circuit. The fill factor is the maximum power divided by the product of the open-circuit voltage and the short-circuit current. A squarer curve gives a higher fill factor and a better cell.

What changes when solar panels are connected in series or in parallel?
In series the voltages add and the current stays that of one panel. In parallel the currents add and the voltage stays the same. Shade on one panel in a series string pulls down the output of the whole string.

How is a fire alarm zone different from a single-station alarm?
A zone groups several detectors and call points on one circuit, so the control panel shows which area raised the alarm. A single-station alarm sounds only at the detector itself. The Fire Alarm Trainer has a conventional two-zone control panel, so students can see which zone raised the alarm.

Why does an alarm keep sounding after the detector has cleared?
The alarm circuit latches. A relay or the control unit holds the alarm on after the detector signal ends, until someone resets the panel. This makes sure a brief alarm is not missed. On many security panels a timer silences the sounder after a set time, but the panel still shows the alarm until it is reset.

Can a solar trainer be installed outdoors at our institute?
The product pages do not say whether the collectors or panels suit outdoor mounting. State in your enquiry whether you need an indoor bench unit or an outdoor set-up. JaincoLab service engineers can install trainers at the customer's site, and a team can give a demonstration to staff. Send the site details through our contact page.

Which panel and battery details should a solar trainer tender state?
State the panel type and rating, the battery type, voltage and capacity, and whether the battery must be sealed for indoor use. The Solar Energy Demonstrator page gives a module of about 40 to 90 W and a 12 V lead-acid battery, but no battery capacity. JaincoLab can also build a trainer to your own technical specification. Send it through our tenders page.

For a quotation, list the trainers with their product codes and the number of sets you need, and send it through our contact page. For tender or project supply, see our tenders page.

Security Alarm Trainer

Security Alarm Trainer

Product Code : JA-LABCS-9618

Security alarm trainer for students and technicians: intruder alarm panel, keypad, PIR detector, door and window contacts, glass-break detector, siren and strobe on a training panel, as a first step to alarm installation work.

View Details
Electronic Control Trainer

Electronic Control Trainer

Product Code : JA-LABCS-9619

Trainer for solid state relays and their applications, with an introduction to semiconductor theory. Zero-cross AC SSR with optocoupler isolation, low-voltage DC control and mains lamp and heater loads.

View Details
Solar Heat Energy Trainer

Solar Heat Energy Trainer

Product Code : JA-LABCS-9620

Compact solar heat trainer for classroom and remote-site use. Students measure the heat a solar panel absorbs in kcal or BTU with a small flat plate collector. They then study collector angle, light intensity and efficiency.

View Details
Solar Energy Trainer, Boiler Type

Solar Energy Trainer, Boiler Type

Product Code : JA-LABCS-9621

Boiler-type solar hot water trainer: flat plate collector, pumped solar circuit and a separate storage boiler with a supplementary electric heater, with a diagram of the solar collection and control circuit.

View Details
Solar Energy Hot Water System Trainer

Solar Energy Hot Water System Trainer

Product Code : JA-LABCS-9622

Solar hot water trainer modelled on household and commercial solar water heaters: collector with an integral hot water storage tank and a supplementary electric heater, for thermosiphon and tank temperature experiments.

View Details
Solar Energy Demonstrator

Solar Energy Demonstrator

Product Code : JA-LABCS-9623

Solar PV demonstrator with a 12 V class module, charge controller, deep-cycle battery and inverter. Students study solar cell operation, battery storage and DC to AC conversion with panel, battery and load meters.

View Details
Training System for DDC Control

Training System for DDC Control

Product Code : JA-LABCS-9624

Training system for direct digital control (DDC) of heating, cooling, lighting, electrical and security services. Programmable controllers with universal I/O, BACnet over Ethernet, sensors, damper actuators and lighting loads.

View Details
Fire Alarm Trainer

Fire Alarm Trainer

Product Code : JA-LABCS-9625

Fire alarm trainer for students and technicians: conventional two-zone control panel, smoke and heat detectors, manual call points, sounder and beacon, with standby battery, on a training panel with operation and experiment manuals.

View Details

Office Address

Jain Scientific Suppliers
2475-84, Hargolal Road,
Ambala Cantt, Haryana, India

[email protected]

+91-85699-09696

Follow Us