Solar Energy Trainer, Boiler Type Manufacturer,Supplier and Exporter in India
Product Code : JA-LABCS-9621
The boiler-type solar energy trainer models a solar hot water heating system of the kind used in homes and commercial buildings. A solar collector heats water that is stored in a separate boiler, which also carries a supplementary electric heater. A diagram of the solar collection and control circuit helps explain how the system works.
Specifications of the boiler-type solar energy trainer
| Product code | JA-LABCS-9621 |
|---|---|
| System type | Solar hot water heating, boiler type, as used in homes and commercial buildings |
| Collector | Flat plate solar collector with a copper absorber and a glass cover |
| Solar circuit | Forced circulation: a pump moves the heat-transfer water from the collector to the boiler |
| Boiler | Separate hot water storage boiler with a heat-exchanger coil and a supplementary electric heater |
| Control | Solar controller (differential thermostat) with temperature sensors on the collector and the boiler, which runs the pump |
| Safety parts | Expansion vessel and pressure relief valve in the solar circuit |
| Instruments | Temperature sensors or thermometers, a flow meter and pressure gauges |
| Teaching aid | Diagram of the solar collection and control circuit |
| Light source and power | Works in sunlight; 230 V AC, 50 Hz single phase for the pump, controller and heater |
| Supplied by | JaincoLab |
Practical work on the boiler-type solar trainer
- Following the circuit. Trace the flow on the circuit diagram from the collector to the boiler coil and back. Then find each pump, sensor and valve on the trainer itself.
- Heat stored in the boiler. Read the boiler temperature every few minutes with a Digital Stem Thermometer while the pump runs. Work out the heat stored from the water volume and the temperature rise.
- Electric heater power. When the thermostat switches the heater on, measure its current with a Digital Clamp Meter. Multiply by the mains voltage to find the heater power.
- Separate or integral tank. Compare the trainer with the Solar Energy Hot Water System Trainer, whose storage tank is built into the unit.
Frequently Asked Questions
When should the supplementary electric heater in the boiler switch on?
Only when the sun has not heated the water enough. Set the heater thermostat below the temperature that the solar circuit usually reaches, or switch the heater by timer shortly before hot water is needed. If it is set too high, the heater does the work that the collector should do.
How can students tell whether the sun or the electric heater is heating the boiler?
Watch the pump and the collector outlet temperature. If the pump runs and the collector is warmer than the boiler, solar heat is going in. If the heater indicator is lit or a clamp meter shows heater current, the element is working. Switching the heater off separates the two clearly.
How does the controller decide when to run the solar circulating pump?
It compares the collector temperature with the boiler temperature. When the collector is hotter by the switch-on difference, the pump starts. When the difference falls to the smaller switch-off value, the pump stops. A high-limit setting also stops it if the boiler gets too hot.
Why is the hottest water found at the top of the storage boiler?
Hot water is less dense than cold water, so it rises and forms layers, with the hottest at the top. This is called stratification. Hot water is drawn off from the top. Cold water enters at the bottom, near the solar coil, where it picks up the most heat.
Which drawings and manuals should come with the boiler-type solar trainer?
The trainer comes with a diagram of the solar collection and control circuit. Also ask for a dimensioned drawing, a parts list and an operation and maintenance manual in your enquiry. JaincoLab provides service manuals with its instruments. The contact page is the place to send this list.
Should our tender state the rating of the electric heater and its thermostat cut-off?
Yes. The trainer has a supplementary electric heater, so state the heater power you need, the thermostat range and an automatic high-temperature cut-off in your tender. This keeps every offer comparable on safety and heating time. Our tenders page takes the full tender schedule.
Other solar energy trainers in the range
For Ministry of Education, World Bank and United Nations laboratory projects, JaincoLab works as manufacturer and exporter and has completed such supplies successfully in many countries. Firms preparing bids for these tenders can request itemised quotations and turnkey supply of the full laboratory scope from our tenders team.
See the Lighting and Building Control Systems range and more electronics lab equipment from JaincoLab, an electronics lab equipment manufacturer in India.
For a quotation, send the product name and the quantity you need through our contact page. For tender or project supply, see our tenders page.