• +91-85699-09696

Industrial PLC System Manufacturer,Supplier and Exporter in India

Industrial PLC System

Product Code : JA-DAIAPC-9611

The Industrial PLC System is a set of industrial programmable logic controller systems offered in several versions. Each version has a different capability and number of inputs and outputs. Students use the chosen version for project work and experimental set-ups in the laboratory. Peripheral devices can be added to extend the system as a course grows.

Specifications of the Industrial PLC System

Product codeJA-DAIAPC-9611
Type and versionsIndustrial programmable logic controller systems in several versions, from a compact CPU with built-in inputs and outputs to an advanced CPU with more I/O, more memory and high-speed functions
UseProject work and experimental set-ups in school, college and training laboratories
Digital inputs and outputs16 or more digital inputs and outputs at 24 V DC on the larger versions; I/O modules take this up to 32 inputs and 32 outputs
Analogue inputs and outputsVoltage (0 to 10 V) or current (4 to 20 mA) signals
High-speed functionsHigh-speed counter inputs and pulse outputs on the advanced versions
Communication and expansionIndustrial Ethernet port on the CPU and an RS-485 serial port on some versions; peripheral devices and I/O modules can be added
ProgrammingPC software with ladder diagram, function block diagram and structured text
Simulator and connectionsSimulator modules with on/off and push-button switches, LEDs and potentiometers for analogue signals; 4 mm safety sockets and patch cords
Operator panel and power supplyOptional 7-inch colour touch screen operator panel (800 x 480 pixels); 230 V AC, 50 Hz single-phase mains with a protection switch and a 24 V DC supply for the PLC and I/O
Supplied byJaincoLab

Using the Industrial PLC System for laboratory projects

  • Sorting line project. Wire the PLC inputs and outputs to the Conveyor System Trainer. Write a program that starts the belt, detects each item as it arrives and sorts it into the right place.
  • Tank level project. Take the 4 to 20 mA level signal of the Level Process Control Trainer into an analogue input. Scale it to percent of span and switch the pump between a low and a high level.
  • Sequence and timer exercises. Use the Programmable Logic Controller Trainer Modular Application Modules as small plant models. Students write step sequences with timers and counters, then test them on the module.
  • Wiring check before power-up. Measure the 24 V DC supply and each input circuit with a Digital Multimeter. Then switch on and confirm that each input LED lights when its switch closes.

Frequently Asked Questions

How many inputs and outputs should we specify, and how much spare capacity should we leave?
List every switch, sensor, lamp, motor and valve in the planned projects. Count the digital and analogue points separately. Then add spare points for changes and new exercises. The larger versions accept extra I/O modules, so a modest base system can grow later.

When does a modular PLC with add-on I/O modules suit a lab better than a compact PLC?
A compact PLC suits fixed, small exercises with a set number of points. Choose a modular system when projects change from term to term, when analogue or high-speed signals are needed, or when the I/O count will grow. Modules can then be added without replacing the CPU.

Why does a current-loop analogue signal start at a live zero instead of zero current?
In a 4 to 20 mA loop, 4 mA means zero on the scale and 20 mA means full scale. A broken wire gives no current at all, so the PLC can tell a fault from a true zero reading. The live zero also lets a two-wire transmitter take its power from the loop.

What kind of projects can students build on an industrial PLC system?
Typical projects are a fluid tank that fills and drains, a washing machine cycle, a conveyor that sorts parts and a traffic junction. Each project starts with a written sequence, then wiring, programming, testing and fault finding. Later projects can add analogue control and a network link.

Which ports should we ask for so the PLC can link to our HMI panels and drives?
The CPU has an industrial Ethernet port, and some versions add an RS-485 serial port. List the make and model of each HMI panel and drive, and the protocol they use, in your enquiry. The matching version can then be quoted. Send the details through our contact page.

Can we get spare I/O modules and parts for the PLC system after supply?
Ask for a list of recommended spares, such as I/O modules, fuses and patch cords, with the quotation. They can then be ordered with the system. JaincoLab service engineers handle installation and after-sales service at your site. Send the version and quantity through our contact page.

Other PLC trainers in the range

See the Data Acquisition, Instrumentation and Process Control range and more electronics lab equipment from JaincoLab, an electronics lab equipment manufacturer in India.

For a quotation, send the product name and the quantity you need through our contact page. For tender or project supply, see our tenders page.

Last updated: 15 November 2026

   

Office Address

Jain Scientific Suppliers
2475-84, Hargolal Road,
Ambala Cantt, Haryana, India

[email protected]

+91-85699-09696

Follow Us