• +91-85699-09696

Level Process Control Trainer Manufacturer,Supplier and Exporter in India

Level Process Control Trainer

Product Code : JA-DAIAPC-9617

The Level Process Control Trainer teaches the basics of process control through level control experiments. Its components sit on a vertical panel with a large-format process diagram. Structured instructional material explains the technology and takes students through each experiment step by step.

Specifications of the Level Process Control Trainer

Product codeJA-DAIAPC-9617
Controlled variable and layoutLevel; components on a vertical panel with a large-format process diagram
Process tankTransparent process tank of about 5 to 18 litres with a graduated level scale, fed from a larger storage tank
PumpSmall electric water pump that circulates water from the storage tank to the process tank
Level measurementDifferential pressure level transmitter at the tank base, or a capacitance probe, with a 4 to 20 mA output
Final control elementPneumatic control valve driven through an I/P converter or positioner; some versions use pump speed control instead
ControllerPID controller with on-off, P, PI and PID modes
Disturbances and recordingManual outlet and bypass valves to change the outflow; chart recorder or PC software for trends and data logging
Services needed230 V AC, 50 Hz mains; compressed air supply for the pneumatic valve
Instructional materialStructured material that explains the technology and guides students step by step through the experiments
Supplied byJaincoLab

Level control experiments on the trainer

  • Open-loop response. With the controller in manual, change the valve opening in one step and record how the level settles. Time the response with a Digital Stop Watch if the recorder is not in use.
  • Transmitter check. Put a Digital Multimeter in series with the transmitter loop. Read the current with the tank empty and full, and compare the readings with the graduated scale.
  • Tuning the loop. Try P, PI and PID modes in turn. Open the outlet valve as a disturbance and note how fast the level returns to the setpoint in each mode.
  • Comparing two loops. Repeat the tuning on the Temperature Process Control Trainer and discuss why a temperature loop responds so much more slowly than a level loop.

Frequently Asked Questions

Which level transmitter suits a teaching tank, a pressure type or a capacitance probe?
For clean water in a teaching tank, a pressure transmitter at the tank base is the usual choice. It is simple to calibrate and easy to explain. A capacitance probe has no moving parts, but it must be set up for the liquid, and coatings on the rod shift its reading.

Why does the level reading change if a liquid other than water is used?
A pressure transmitter measures the weight of liquid above it, which depends on density as well as height. A denser liquid reads higher than water at the same level, and a lighter one reads lower. Recalibrate the transmitter for the specific gravity of the new liquid.

What happens to the level loop when the proportional band is set too narrow?
A narrow proportional band means high gain, so the valve swings hard for every small error. The level overshoots, then undershoots, and may keep oscillating around the setpoint. Widen the band until the level settles with only a small overshoot.

How do we keep the water in the level trainer clean between practicals?
Fill the trainer with clean, soft water and drain it when it will stand unused for some days. Stagnant water grows algae, especially in light, and hard water leaves scale on the tank and probe. Rinse the tanks and check the water before each term starts.

Does the level trainer need its own air compressor for the control valve?
A version with a pneumatic control valve needs a clean, dry compressed air supply with a regulator and filter. If your lab has no air line, ask for a compressor in your enquiry so that it is quoted with the trainer. Our contact page takes such requests.

Is a PC needed to run the data logging software of the level trainer?
The trend and logging software runs on a PC, while a chart recorder version needs none. Say in your enquiry whether your lab will provide the PC or wants one included. JaincoLab service engineers can install the software and show your staff how to log a run.

Other process control trainers in the range

Companies bidding for Ministry of Education, World Bank or United Nations laboratory tenders can work with JaincoLab as their manufacturing partner: we make and export complete laboratory packages for such projects and have executed them successfully in many countries. Send the tender specification through our tenders page for a quotation.

See the Data Acquisition, Instrumentation and Process Control range and more electronics lab equipment from JaincoLab, an electronics lab equipment manufacturer in India.

For a quotation, send the product name and the quantity you need through our contact page. For tender or project supply, see our tenders page.

Last updated: 16 November 2026

   

Office Address

Jain Scientific Suppliers
2475-84, Hargolal Road,
Ambala Cantt, Haryana, India

[email protected]

+91-85699-09696

Follow Us